   DIRECT TEST METHOD TO TEST LEAD ON HAND AND OTHER SURFACES               

Step 1: Spray the hand or other surface 4-5 times with Solution 1

Step 2: Spray the hand or other surface Solution 2


If lead is present on the hand or other surface, the surface will show an immediate color change to yellow. The yellow color on the hand or surface shows the exact location of the lead present.

Back to top

   INDIRECT TEST METHOD TO TEST LEAD ON HAND AND OTHER SURFACES           

Step 1: Spray the entire cotton test pad 6-8 times with Solution 1
Step 2: Wipe the hand or surface to be tested
If lead is present on the tested surface, the test pad will show an immediate color change to yellow.
Step 3: Spray the entire test pad 5-7 times with Solution 2


   sample Control pad                                                                                               

The Control Pad contains four spots of lead. There are two spots at approximately 20 micrograms and two spots at approximately 100 micrograms. To run a control test, spray the Control Pad with Solution 2. A color change to yellow will occur. A similar color change occurs when lead is present on the test surface.
   CLEANING LEAD CONTAMINATION FROM HAND OR OTHER SURFACES               
If the test results are positive, clean the lead contaminated area with D-Wipe® Towels or with a D-Lead® Cleaning product and dispose of test pads and D-Wipe® Towels as required by regulations.
 
ESCA Tech, Inc. assumes no liability for misuse of the product or interpretation of the results by the user. The warranty is limited to a refund of the purchase price of the product only. Test results should be confirmed by chemical analysis.
   
 